DEFORMATION MONITORING OF NEW AUDITORIUM FEDERAL SCHOOL OF SURVEYING, OYO

Student: Quadri Babatunde Bolaji
Supervisor: Surv Kayode Oyeniyi Odedare
HOD: Surv Jeleel Aderibigbe Qaadri
Department of Surveying and Geo-Informatics
Geospatial Science
Federal School of Surveying, Oyo, Oyo State

Abstract

A deformation survey is a specialized aspect of engineering surveying concerned with the precise observation and analysis of structural movements over time. It involves accurately determining positional, dimensional, and shape variations in a structure to assess its geometric stability and identify deformations that could affect safety or functionality. Essentially, deformation monitoring acts as a diagnostic tool for evaluating the structural health of a building, allowing early detection of physical changes resulting from environmental factors, loading conditions, foundation settlement, or material fatigue. In this study, a geodetic control network was established around the newly constructed auditorium at the Federal School of Surveying, Oyo, to monitor its structural behavior. Observations were carried out at multiple epochs using high-precision geodetic instruments, including a Total Station, Digital Level, and GNSS receivers. The collected data were processed and analyzed using Leica Infinity, AutoCAD, and Microsoft Excel for coordinate adjustment, displacement computation. The results revealed minor horizontal and vertical displacements within acceptable engineering tolerances. However,slight movement trends were observed, underscoring the importance of continuous monitoring to prevent potential long-term deformation. The study concludes that periodic deformation surveys and preventive maintenance are essential for ensuring the long-term stability, safety, and functionality of the building. Furthermore, the research highlights the effectiveness of integrating multiple geodetic techniques and analytical tools in deformation monitoring, providing a practical framework for similar structural assessment projects. The building covers a total area of 857.5101m2 and has a height of 36.6480m. The observed millimeter variations indicate that the building is not considered stable, possibly resulting from measurement inaccuracies or environmental hazards; Hence,periodic monitoring is recommended to prevent potential structural failure or damages

Full-Text Access Notice

In accordance with the NERD Policy on promoting peer-reviewed publication, public access to the full text of a project, thesis or dissertation is restricted for three years, allowing the author and supervisors sufficient time to pursue peer-reviewed publication. During this period, researchers with legitimate academic or research purposes may request authorisation directly from the author to enable NERD to release the indexed full texts of the work using the form below.

Request authorisation from the author